Probides protection against earth fault/leakage current and function of isolation.
High short-circuit current withstand capacity
Applicable to terminal and pin/fork type busbar connection
Contact position indication
Equipped with finger protected connection teminals
Fire resistant plsstic parts endures abnormal heating and strong impact
Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.
Independent of power supply and line voltage, and free from extermal interference, voltage fluctuation.
Construction and Feature
Probides protection against earth fault/leakage current and function of isolation.
High short-circuit current withstand capacity
Applicable to terminal and pin/fork type busbar connection
Contact position indication
Equipped with finger protected connection teminals
Fire resistant plsstic parts endures abnormal heating and strong impact
Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.
Independent of power supply and line voltage, and free from extermal interference, voltage fluctuation.
Technical Data
Mode: electro-magnetic type,electronic type
Residual current characteristics: A,AC
Pole NO:2,4
Rated making and breaking capacity: 500A(In=25A,32A,40A)or 630A(In=63A)
Rated current(A): 25,40,63
Rated voltage: AC 230(240)/400(415)V
Rated frequency: 50/60Hz
Rated residual operating current I△n(A):0.03,0.1,0.3,0.5
Rated residual non operating current I△no:0.5 I△n
Rated conditional short-circuit current Inc: 10kA
Rated conditional residual short-circuit Current I△c: 10kA
Tripping duration:instantaneous tripping≤0.3s(0.1)
Residual tripping current range: 0.5I△n~I△n
Terminal Connection Height: 21mm
Electro-mechanical endurance:4000 cycles
Connection capacity: Rigid conductor 25mm²
Connection terminal: Screw terminal
Pillar terminal with clamp
Fastening torque:2.0Nm
Installation:
On symmetrical DIN rail 35.5mm
Panel mounting
Protection class:IP20
Construction and Feature
Probides protection against earth fault/leakage current and function of isolation.
High short-circuit current withstand capacity
Contact position indication
Equipped with finger protected connection teminals
Fire resistant plsstic parts endures abnormal heating and strong impact
Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.
Independent of power supply and line voltage, and free from extermal interference, voltage fluctuation.
Technical Data
Mode: electro-magnetic type,electronic type
Residual current characteristics: A,AC
Pole NO:2,4
Rated making and breaking capacity: 500A(In=25A,40A)or 10InA(In=63A,80A,100A,125A)
Rated current(A): 25,40,63
Rated voltage: AC 230(240)/400(415)
Rated frequency: 50/60Hz
Rated residual operating current I△n(A):0.03,0.1,0.3,0.5
Rated residual non operating current I△no:0.5 I△n
Rated conditional short-circuit current Inc: 10kA
Rated conditional residual short-circuit current I△c:10kA
Tripping duration:instantaneous tripping≤0.3s(0.1)
Residual tripping current range: 0.5I△n~I△n
Electro-mechanical endurance:4000 cycles
Connection capacity: Rigid conductor 25mm²
Teminal Connection Height:21mm
Connection terminal:
Pillar terminal with clamp
Fastening torque:2.0Nm
Installation:
On symmetrical DIN rail 35.5mm
Panel mounting
Protection class:IP20